Pre-owned TEM microscopes

Compare configurations, browse photographs and entrust your search to 2Cnano.

Availability and configuration to be confirmed by 2Cnano · Price on request.

60 references

PHILIPS EM420 — unit 2CN-057
TEM2CN-057

PHILIPS EM420

PHILIPS · Year: 1985

Requires repair / inspection

Thermionic LaB6 or tungsten depending on configuration; 40–120 kV

Cannot find the right system?

Describe your application, required detectors, budget and timeline. 2Cnano will assess your sourcing or trade-in enquiry.

SEM · 2Cnano reference 2CN-001

FEI Magellan 400L XHR FEG SEM + EDS

FEI · 2010 · Reported operational

Availability to be confirmed · Price on request

Source & voltageUC monochromated Schottky FEG; 50 V–30 kV; 1 pA–22 nA
Stated resolution0.8 nm at 15 kV; 0.9 nm at 1 kV; 1.5 nm at 200 V; STEM 0.5 nm at 30 kV
Detection & analysisETD, TLD, vCD, BF/DF/HAADF STEM; Oxford X-Max 20 mm² / INCA 450
Stage & samples5 piezo axes; X/Y 100 mm; Z ≥20 mm; tilt −10°/+60°; continuous rotation
Accessories & configurationAutomated load lock, plasma, ThermoFlex 900, oil-free pumping, sample holders and PC

Condition, exclusions & points to check

FEG source replaced in September 2026, load lock in June 2026; PC/high-voltage upgrade in 2021. Deinstallation reported possible until mid-December 2026. Tests and documents subject to confidentiality.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-002

FEI Nova NanoSEM 200 FEG

FEI · 2006 · Deinstalled

Availability to be confirmed · Price on request

Source & voltageSchottky FEG; 200 V–30 kV, 100 V steps
Stated resolution1.0 nm at 15 kV, WD 4.6 mm; 1.8 nm at 1 kV, WD 1 mm, specification values
Detection & analysisETD, TLD, LVD, BSED, GAD; EDS EDAX PV7761/96 10 mm²; IR camera
Stage & samplesTravel configuration to be specified
Accessories & configurationTurbo, scroll and ion pumps; Fischione cold trap; PC and accessories box

Condition, exclusions & points to check

Reinstallation and acceptance tests to be defined. Resolution values are not a current performance measurement of this unit.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-003

FEI Tecnai F30 TWIN 300kV FEG TEM

FEI · 2005 · Requires repair / inspection

Availability to be confirmed · Price on request

Source & voltageFEG; 80–300 kV
Stated resolutionPoint resolution 0.2 nm; line resolution 0.14 nm
Detection & analysisFEI CETA CMOS camera; HAADF STEM
Stage & samplesCompuStage; travel and tilt not specified
Accessories & configurationChiller, standard sample holder; optional UPS

Condition, exclusions & points to check

FEG emitter at end of life and requires replacement. Visible Gatan GIF filter EXCLUDED. Preventive maintenance August 2026; manufacturer contract until December 2025. Availability stated around the end of Q1 2027.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-004

FEI NOVA NanoSEM 230 FESEM

FEI · 2008 · Reported operational

Availability to be confirmed · Price on request

Source & voltageSchottky FEG; landing energy 50 V–30 kV
Stated resolution1.0 nm at 15 kV; 1.6 nm at 1 kV, TLD-SE at optimum WD
Detection & analysisTLD-SE/BSE, SED, LVD, IR-CCD, vCD
Stage & samples4 motorised axes; X/Y 50 mm; Z 50 mm including 25 mm motorised; manual tilt −15°/+75°; continuous rotation; 2 µm repeatability
Accessories & configurationChiller, pump, sample holders, manual interface and joystick

Condition, exclusions & points to check

Maintenance and FEG replacement reported in June 2024; FEI service contract reported.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-005

FEI Quanta 400 FEG ESEM

FEI · 2005 · Reported operational

Availability to be confirmed · Price on request

Source & voltageFEG; 200 V–30 kV; current up to 100 nA
Stated resolution2 nm at 30 kV in high vacuum; 3.5 nm at 3 kV in low vacuum, manufacturer’s acceptance specifications
Detection & analysisSED, LFD, SSBSED; GAD listed as an option
Stage & samples5 axes; X/Y 100 mm; Z 60 mm; tilt −5°/+70°; 360° rotation; analytical WD 10 mm
Accessories & configurationHeating and cooling stages; 240 l/s TMP and two backing pumps

Condition, exclusions & points to check

Reported operational, sample trial possible. FEG source reported new, Sirion FEG column. Analytical configuration to be confirmed.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-006

FEI Quanta 450 ESEM

FEI · 2012 · Deinstalled

Availability to be confirmed · Price on request

Source & voltageTungsten filament; high-vacuum, low-vacuum and ESEM modes
Stated resolutionSE: 3 nm at 30 kV; 8 nm at 3 kV in high vacuum; 10 nm at 3 kV in low vacuum
Detection & analysisSED, LFD, GSED, IR camera; BSE, vCD and other detectors marked optional or subject to confirmation
Stage & samplesX/Y 100 mm; Z 60 mm; 75 mm clearance; tilt −5°/+70°; continuous rotation; XY repeatability 2 µm
Accessories & configurationPC, manual interface, joystick

Condition, exclusions & points to check

Items marked with an asterisk in the original configuration are not stated as included: exact contents must be checked.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-007

HITACHI S-4700 TYPE II FEG

HITACHI · 2001 · Packed / crated

Availability to be confirmed · Price on request

Source & voltageCold FEG; 500 V–30 kV
Stated resolutionValue not specified in the documentation
Detection & analysisUpper/lower SE detectors, SE/BSE mixing, YAG-BSE, EBIC
Stage & samples5 motorised axes; X 100 / Y 50 / Z 30 mm; 60° tilt; 360° rotation; maximum diameter 150 mm
Accessories & configuration6-inch load lock, cryogenic anticontamination trap, IR camera, console and Windows XP PC

Condition, exclusions & points to check

Instrument packed / crated. Deinstallation reported by a Hitachi Europe service provider; no reported fault, detailed history not provided.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-008

PHILIPS CM120

PHILIPS · 1990 · Reported operational

Availability to be confirmed · Price on request

Source & voltageLaB6 stated; 60–120 kV, maximum 120 kV
Stated resolutionPoint resolution 0.34 nm; line resolution 0.20 nm, model data
Detection & analysisDetection not specified; chemical analyser excluded
Stage & samplesCompuStage; model tilt stated up to ±70°, to be checked for the sample holder
Accessories & configurationSingle-tilt sample holder

Condition, exclusions & points to check

Reported operational. Annual preventive maintenance, last visit listed as December 2025. No chemical analyser.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-009

JEOL JSM-7401F FEG SEM

JEOL · 2005 · Installed · shut down

Availability to be confirmed · Price on request

Source & voltageCold FEG; 0.1–30 kV
Stated resolution0.8 nm at 15 kV; 1.6 nm at 1 kV
Detection & analysisStandard and in-lens SE; Gentle Beam mode; EDS not installed
Stage & samples5 motorised axes; XY travel approx. 100 mm; tilt −5°/+70°
Accessories & configurationLN₂ cold trap, two column turbo pumps, dual-screen workstation

Condition, exclusions & points to check

Installed and shut down. Addition of EDS and availability of low-voltage mode to be confirmed.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-010

FEI SIRION 200 SFEG

FEI · 2003 · Deinstalled

Availability to be confirmed · Price on request

Source & voltageSFEG; 500 V–30 kV; magnification ×30–×600,000
Stated resolution1.5 nm from 10 kV; 2.5 nm at 1 kV
Detection & analysisSE, BSE and in-lens; acquisition up to 4K × 3K TIFF
Stage & samplesXY 50 × 50 mm; 360° rotation; tilt −15°/+75°, limited to +45° for large samples; WD 1–60 mm; 5 controlled axes
Accessories & configurationPeripheral configuration to be specified

Condition, exclusions & points to check

Electron column reportedly replaced in 2022; FEI maintenance reported. Instrument deinstalled.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-011

Hitachi HD-2700 Transmission Electron Microscope

HITACHI · 2010 · Reported operational

Availability to be confirmed · Price on request

Source & voltageDedicated Cs-corrected STEM, cold FEG; 80/120/200 kV
Stated resolution1.05 Å at 200 kV
Detection & analysisGatan Orius SC1000W, HAADF/MAADF/DF/BF/SE; EDAX SiLi 30 mm²; Enfina EELS 0.8 eV
Stage & samplesSingle/double-tilt, heating, cryotransfer, Faraday, calibration, tomography rotation and revolver sample holders
Accessories & configurationTomography; DigitalMicrograph and EDAX Genesis

Condition, exclusions & points to check

Operation reportedly tested at 200 kV in April 2025. Exact stage travel and peripherals not documented; generic fields should not be taken as included equipment.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-012

JEOL JEM-2100 TEM

JEOL · 2005 · Installed · shut down

Availability to be confirmed · Price on request

Source & voltageLaB6; 80–200 kV
Stated resolutionPoint resolution 0.23 nm; line resolution 0.14 nm
Detection & analysisBright-field and dark-field stated
Stage & samplesStandard goniometer, ±25° tilt; 5-axis motorised stage
Accessories & configurationCamera and accessories not specified

Condition, exclusions & points to check

Installed and shut down; current condition and restart to be checked.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-013

FEI Tecnai G2 F30 TWIN 300kV FEG TEM

FEI · 2002 · Packed / crated

Availability to be confirmed · Price on request

Source & voltageFEG; 300 kV
Stated resolutionPoint resolution 0.24 nm; line resolution 0.14 nm
Detection & analysisGatan UltraScan 4000 UHS multiport for 300 kV
Stage & samples5 axes; single tilt, tomography and double tilt; up to ±70° with a suitable sample holder
Accessories & configurationChiller; diffusion and turbo pumps; compressor not supplied

Condition, exclusions & points to check

Unit packed / crated. Contents and recommissioning tests to be specified.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-014

FEI Tecnai T20 Sphera

FEI · 2000 · Packed / crated

Availability to be confirmed · Price on request

Source & voltageLaB6 or tungsten depending on setup; 80–200 kV
Stated resolutionPoint resolution 0.27 nm; line resolution 0.144 nm, subject to environmental conditions
Detection & analysisFEI Eagle 4K USB
Stage & samplesXY 2 mm; Z 750 µm; tilt −70°/+70°; single-tilt sample holder
Accessories & configurationCryobox, low dose; oil-free accelerator/column pumping

Condition, exclusions & points to check

Cryogenic sample holder not included. Unit packed / crated; installed emitter to be confirmed.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-015

FEI Tecnai G2 F20 FEG

FEI · 2005 · Reported operational

Availability to be confirmed · Price on request

Source & voltageSchottky FEG; stated 80–200 keV; S-TWIN objective
Stated resolutionPoint resolution 0.24 nm; line resolution 0.102 nm; HAADF STEM 0.19 nm; stated information limit 0.14 nm
Detection & analysisGatan UltraScan 1000 2K; Fischione 3000 HAADF; EDAX Apollo XLT2 30 mm²
Stage & samplesCompuStage; XY travel 2 mm; 3 mm sample; tilt depends on sample holder
Accessories & configurationChiller, compressor, pumps, single-tilt and low-background double-tilt sample holders

Condition, exclusions & points to check

Reported operational; service contract indicated until 31 December 2024. Consistency of resolution values to be confirmed in the acceptance documentation.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-016

FEI Tecnai G2 F20 + GIF

FEI · 2005 · Reported operational

Availability to be confirmed · Price on request

Source & voltageSchottky FEG; 20–200 kV
Stated resolutionTEM point resolution 0.24 nm; line resolution 0.102 nm; HAADF-STEM 0.19 nm
Detection & analysisGatan US1000; Tridiem ER filter; EDAX TEC 30T/30ST 30 mm²; STEM interface
Stage & samplesCompuStage; XY ±1 mm; Z ±0.375 mm; up to ±80° with a tomography sample holder
Accessories & configurationTomography; Nanomegas P2000 and external Flucam

Condition, exclusions & points to check

Availability stated in December 2026; in use, Thermo Fisher maintenance reported. No photograph published in the reviewed listing.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-017

Tescan Vega 2 LMU SEM

TESCAN · 2008 · Reported operational

Availability to be confirmed · Price on request

Source & voltageTungsten; 200 V–30 kV; current up to approx. 2 µA
Stated resolution3.5 nm at 30 kV SE; 4.5 nm at 30 kV BSE
Detection & analysisLVST, 4-quadrant BSE, chamber camera; Oxford INCA 250 XT / x-act, 133 eV at 5.9 keV
Stage & samplesMotorised stage with rotation and tilt; up to 7 stubs
Accessories & configurationTrackball, pumping, Windows XP PC; Tescan 3.4.2.1 and INCA 4.12

Condition, exclusions & points to check

Operation and demonstration reported; legacy software should be considered for IT integration.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-018

JEOL JSM 6490LV with EDS

JEOL · 2008 · Deinstalled

Availability to be confirmed · Price on request

Source & voltageTungsten; 0.3–30 kV, 55 steps; approx. 1 pA–1 µA
Stated resolutionHV: 3 nm at 30 kV, WD 8 mm; LV-BEI: 4 nm at 30 kV, WD 5 mm
Detection & analysisE.T. SE, semiconductor BSE; Bruker Quantax 250, software 1.9.4
Stage & samples5 axes; X 125 / Y 100 mm; WD 5–80 mm; tilt −10°/+90°; 360° rotation; sample up to 8 inches, 1 kg
Accessories & configurationTwo rotary pumps, diffusion pump, foreline trap, Pirani gauge, sample holders

Condition, exclusions & points to check

Reported functional before storage. Reinstallation for demonstration reportedly possible; microscope software 8.27.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-019

FEI Nova NanoSEM 450 FEG

FEI · 2012 · Installed · shut down

Availability to be confirmed · Price on request

Source & voltageFEG; exact source and voltage range to be confirmed
Stated resolutionHV: 0.8 nm at 30 kV STEM; 1 nm at 15 kV TLD-SE; 1.4 nm at 1 kV without deceleration; LV: 1.5 nm at 10 kV
Detection & analysisTLD-SE/BSE, SED, LVD, IR-CCD, DBS and GAD stated
Stage & samples5 axes; XY 110 mm; Z 25 mm; tilt −15°/+75°; repeatability <2 µm; sample Ø150 mm; 500 g in all positions, 2 kg at 0°
Accessories & configurationCarbon and platinum GIS, plasma, PC and manual interface

Condition, exclusions & points to check

Installed and shut down; power-up reportedly possible. Measurement conditions and detector configuration to be confirmed.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-020

FEI Nova NanoSEM 600 FEG

FEI · 2009 · Installed · shut down

Availability to be confirmed · Price on request

Source & voltageThermal / Schottky FEG; 200 V–30 kV
Stated resolution≤1 nm at 15 kV, WD 4.6 mm; ≤1.8 nm at 1 kV, WD 1 mm
Detection & analysisTLD, SED, BSE, LVD, retractable STEM
Stage & samples5 axes; XY 150 mm; 55 mm clearance; tilt −10°/+60°; stated step size 100 nm
Accessories & configurationTurbo pumping and vacuum pump

Condition, exclusions & points to check

Chiller and compressor not included. Reported operational; stated refurbishment of hoses, alignment and pump to be confirmed in the service scope.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-021

ZEISS LEO 1530 FEG – Upgraded as Supra 40

ZEISS · 2000 · Deinstalled

Availability to be confirmed · Price on request

Source & voltageLEO 1530, upgraded to a Supra 40 configuration in 2015
Stated resolutionValues not specified
Detection & analysisBSE and HDASB stated
Stage & samplesDual-joystick control; travel to be specified
Accessories & configurationChiller, computer; Windows 7 and SmartSEM 6.0

Condition, exclusions & points to check

Upgrade: PC, electronic calibration, scan generator and console replaced. Deinstalled; reinstallation to be assessed.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-022

JEOL JSM-IT100LA + EDS

JEOL · 2018 · Reported operational

Availability to be confirmed · Price on request

Source & voltageTungsten; 0.5–20 kV, 43 steps; current 1 pA–1 µA
Stated resolutionHV-SE 3.7 nm at 20 kV / 5.5 nm at 5 kV; LV-BSE 4.8 nm at 20 kV
Detection & analysisSE, BSE NIP; LN₂-free JEOL Dry SD25 EDS, 25 mm², 129 eV at Mn Kα
Stage & samplesMotorised XYZ: X80/Y40 mm, Z5–48 mm; tilt −10°/+90°; manual rotation; sample Ø150 mm, 1.5 kg
Accessories & configurationInTouchScope, navigation and IR camera, two touchscreens, PC, pumping; low vacuum 10–100 Pa

Condition, exclusions & points to check

Reported operational; version 1.100. No water cooling required according to documentation. Service history available.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-023

FEI Quanta 200 FEG MK1

FEI · 2004 · Deinstalled

Availability to be confirmed · Price on request

Source & voltageSchottky FEG; 200 V–30 kV
Stated resolution3.5 nm at 3 kV in low vacuum; 2 nm at 30 kV in high vacuum
Detection & analysisChamber ETD and BSD
Stage & samplesXY −25/+25 mm; Z25+25 mm mechanical/motorised; 360° rotation; tilt −15°/+75°; 1 kg at 0°, 250 g otherwise
Accessories & configurationMicromanipulator, Windows 2000 PC; ESEM mode stated

Condition, exclusions & points to check

2004 unit deinstalled. Reportedly in good condition; stated FEG tip replacement to be confirmed in the quotation.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-024

FEI Tecnai G2 F20 FEG

FEI · 2003 · Deinstalled

Availability to be confirmed · Price on request

Source & voltageSchottky FEG; 80–200 kV
Stated resolutionPoint resolution 0.27 nm; line resolution 0.144 nm; information limit 0.18 nm, depending on environment
Detection & analysisNo detector stated
Stage & samplesXY 2 mm; Z750 µm; α tilt −80°/+80°
Accessories & configurationNo accessory stated; Windows XP interface and script control

Condition, exclusions & points to check

2003 unit deinstalled, separate from the 2005 F20. Camera and detection equipment must be provided or confirmed; do not assume accessories from another listing.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-025

PHILIPS CM10

PHILIPS · 1990 · Reported operational

Availability to be confirmed · Price on request

Source & voltageLaB6 stated; 40–100 kV
Stated resolutionPoint resolution 0.5 nm; line resolution 0.34 nm
Detection & analysisNot specified; chemical analyser excluded
Stage & samplesEucentric goniometer ±60° stated for the model; travel not specified
Accessories & configurationSingle-tilt sample holder

Condition, exclusions & points to check

Reported operational; last preventive maintenance February 2026. Chemical analysis configuration not included.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

FIB-SEM · 2Cnano reference 2CN-026

FEI Helios NanoLab 600i FIB-SEM Dual Beam

FEI · 2011 · Deinstalled

Availability to be confirmed · Price on request

Source & voltageSchottky Elstar; SEM 350 V–30 kV, landing energy 20 V–30 kV with deceleration; Tomahawk Ga⁺ 0.5–30 kV
Stated resolutionSEM 0.9 nm at 15 kV / 1.4 nm at 1 kV; FIB 4 nm at 30 kV
Detection & analysisTLD SE/BSE, SED/ETD, ICE, current measurement, IR camera
Stage & samples5 piezo axes; XY 150 mm; Z 10 mm; tilt −10°/+60°; continuous rotation; XY repeatability 1 µm
Accessories & configurationPlasma, XDS35i, AutoProbe 200, two PCs, screens, joystick; xT 5.x software

Condition, exclusions & points to check

Deinstalled, system reportedly complete. Manufacturer contract reported during operation; recommissioning to be defined.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-027

Philips XL30 SFEG Sirion Electron Microscope

PHILIPS · 1999 · Requires repair / inspection

Availability to be confirmed · Price on request

Source & voltageFEG; 30 kV stated
Stated resolutionNot provided
Detection & analysisSE, camera and monochromatic cathodoluminescence
Stage & samplesManual XYZ with tilt and rotation
Accessories & configurationVacuum pumps and computer

Condition, exclusions & points to check

Communication fault reported, suspected to originate on an electronic board. No recent maintenance listed; functional condition requires diagnosis.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-028

FEI Quanta 200 W SEM

FEI · 2005 · Requires repair / inspection

Availability to be confirmed · Price on request

Source & voltageTungsten; 1–30 kV
Stated resolutionTest of 26 January 2026: 100 nm on tin/carbon with BSE, reported result
Detection & analysisLFD, GSED, GBSD, GAD; LN₂-cooled Oxford INCA-350 Si(Li)
Stage & samplesXY 50 mm; 4 motorised axes; Z 25 mm; manual tilt −15°/+75°
Accessories & configurationTwo backing pumps, TMP, 1,000/1,500 °C heating and Peltier stages; maintenance kit

Condition, exclusions & points to check

SE and BSE faulty. Low-vacuum/ESEM modes not functional. Chiller and compressor not supplied. Repairs to be quoted.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-029

JEOL JEM 1200 EX

JEOL · 2000 · Requires repair / inspection

Availability to be confirmed · Price on request

Source & voltageSource configuration and voltage not specified
Stated resolutionNot provided
Detection & analysisEDS SGX Sensortech SD-10128LE-IS
Stage & samplesNot documented
Accessories & configurationAssociated parts instrument under a separate reference

Condition, exclusions & points to check

The system does not start. Diagnosis and refurbishment required; must not be presented as operational.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-030

JEOL 2010 (2011 version) Lab6

JEOL · 2000 · Installed · shut down

Availability to be confirmed · Price on request

Source & voltageLaB6; 80–200 kV; UHR objective; MDS low-dose system
Stated resolution1.9 Å and 1.4 Å stated; the nature of both criteria must be confirmed
Detection & analysisGatan UltraScan 2K and film
Stage & samples±45° with standard sample holder; ±20° with Gatan 626 cryo holder; double tilt depending on setup
Accessories & configurationFull pumping system; standard and JEOL EM31031 double-tilt sample holders

Condition, exclusions & points to check

No fault reported; continuous JEOL maintenance stated. Installed and shut down; power-up possible according to documentation.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-031

TFS Phenom XL Desktop SEM

TFS · 2019 · Reported operational

Availability to be confirmed · Price on request

Source & voltageFirst-generation Phenom XL; 5/10/15 kV presets; advanced mode 4.8–20.5 kV
Stated resolution<14 nm stated
Detection & analysisSE, BSE, EDS reportedly new in 2026, optical navigation
Stage & samplesMotorised stage; samples up to 100 × 100 mm
Accessories & configurationBacking pump, PC, screens, keyboard, mouse, manual sample holder

Condition, exclusions & points to check

Former demonstration unit; periodic preventive maintenance stated. Exact EDS configuration to be confirmed.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-032

Thermo Fisher Glacios Cryo-TEM

TFS · 2021 · Requires repair / inspection

Availability to be confirmed · Price on request

Source & voltageX-FEG; 80–200 kV; Cryo Twin objective
Stated resolutionStated information limit 0.23 nm without tilt and 0.34 nm at ±70°
Detection & analysisFalcon 4 and Ceta-D
Stage & samplesCompuStage Mark I; ±1,000 µm travel; ±70° tilt; autoloader
Accessories & configurationTomography, low dose, Phase Plate Type II, three motorised aperture mechanisms

Condition, exclusions & points to check

Autoloading errors related to the back-docker’s ceramic pins. Repair stated as part of refurbishment, to be specified contractually.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-033

HITACHI HT7700 EXALENS

HITACHI · 2009 · Reported operational

Availability to be confirmed · Price on request

Source & voltageLaB6; 40–120 kV; dual-gap contrast/resolution objective
Stated resolutionPoint resolution 0.204 nm; line resolution 0.144 nm
Detection & analysisPeltier-cooled AMT XR81B 8 Mpix; BF/DF STEM; tomography
Stage & samplesXYZ ±1 mm; single tilt ±30°; double tilt α ±30° / β ±15°
Accessories & configurationRotary and diffusion pumps; chiller

Condition, exclusions & points to check

Availability stated for 2027–2028. Good operation and Hitachi maintenance reported; must not be advertised as immediately available.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-034

JEOL JEM 1400 TEM

JEOL · 2007 · Reported operational

Availability to be confirmed · Price on request

Source & voltageLaB6; 40–120 kV
Stated resolutionPoint resolution 0.38 nm; line resolution 0.2 nm
Detection & analysisTop-mounted Gatan Orius 600; JEOL JED-2300 EDS
Stage & samplesTravel not specified; high-tilt sample holder for tomography
Accessories & configurationBeryllium sample holder for microanalysis; stated electrical power 10 kVA

Condition, exclusions & points to check

Manufacturer maintenance stated; last preventive maintenance April 2026, high voltage conditioned to 120 kV.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-035

JEOL JEM-2011 TEM

JEOL · Not specified · Deinstalled

Availability to be confirmed · Price on request

Source & voltageLaB6; up to 200 kV
Stated resolutionPoint resolution 0.23 nm; line resolution 0.14 nm
Detection & analysisBottom-mounted AMT CCD 2MB; horizontal EDAX EDS with ultrathin window; listed SE to be checked
Stage & samples5-axis motorised goniometer; ±30° tilt
Accessories & configurationHX-150 chiller and Windows PC

Condition, exclusions & points to check

Reported operational with no fault; refurbishment before packing stated. Deinstalled; year not provided.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-036

JEOL JEM 1011 + EDS

JEOL · 2003 · Installed · shut down

Availability to be confirmed · Price on request

Source & voltageSource and voltage not specified
Stated resolutionStated EDS resolution 133 eV; reference energy not specified
Detection & analysisSGX Sensortech Sirius SD-10129LE-IS; active area 10 mm²; AP3.3 window
Stage & samplesNot documented
Accessories & configurationContents to be specified

Condition, exclusions & points to check

Installed and shut down; listing limited to EDS analysis. TEM performance must not be inferred from this EDS value.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-037

JEOL JEM-2010F(CR) TEM

JEOL · 2000 · Requires repair / inspection

Availability to be confirmed · Price on request

Source & voltageFEG; 80–200 kV; Cryo CR objective, HCOA and Super MDS
Stated resolutionPoint resolution 2.3 Å; lattice resolution 1.4 Å
Detection & analysisGatan K2 HS camera
Stage & samplesGatan 626 cryo holder ±60°; JEOL cryo sample holder ±70°
Accessories & configurationFull pumping system and sample holders

Condition, exclusions & points to check

K2 camera digitiser out of service. Microscope reportedly functional apart from this fault; continuous JEOL maintenance reported.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-038

FEI Tecnai T12 Transmission Electron Microscope

FEI · 2009 · Reported operational

Availability to be confirmed · Price on request

Source & voltageTungsten; 20–120 kV
Stated resolutionPoint resolution 0.34 nm; line resolution 0.20 nm
Detection & analysisAMT CCD; Tietz F214 2K × 2K reported out of service
Stage & samplesXY ±1,000 µm; 70° tilt
Accessories & configurationCabinet, diffusion pump, 70° room-temperature sample holder, cryo sample holder, Windows 2000 PC

Condition, exclusions & points to check

Tietz F214 camera not functional. Compressor not included. Microscope reportedly operates well; previous FEI contract listed.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-039

PHILIPS CM20 Ultra Twin

PHILIPS · 1993 · Reported operational

Availability to be confirmed · Price on request

Source & voltageLaB6; S/TEM 200 kV
Stated resolutionNot provided
Detection & analysisOlympus MegaView G3 CCD; PGT EDS
Stage & samplesSingle tilt ±12°; double tilt α/β ±12°
Accessories & configurationNeslab HX300A and Engie ZEM500SW chillers

Condition, exclusions & points to check

Reported operational. Manufacturer contract until 2017 followed by inspections; IGP, diffusion pump and gun replaced in 2021.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-040

JEOL JEM 1200 EX (parts)

JEOL · Not specified · For parts

Availability to be confirmed · Price on request

Source & voltageEquipment intended for parts
Stated resolutionNo functional performance stated
Detection & analysisIncomplete contents
Stage & samplesDismantled
Accessories & configurationParts and subassemblies according to inventory

Condition, exclusions & points to check

Dismantled and incomplete, FOR PARTS ONLY. Sale stated only together with the associated JEM1200EX unit; terms to be confirmed.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-041

PHILIPS CM120

PHILIPS · 1995 · Installed · shut down

Availability to be confirmed · Price on request

Source & voltageLaB6 stated; 60–120 kV, maximum 120 kV
Stated resolutionPoint resolution 0.34 nm; line resolution 0.20 nm, model data
Detection & analysisChemical analyser excluded
Stage & samplesCompuStage; model tilt up to ±70°, setup to be confirmed
Accessories & configurationSingle-tilt sample holder

Condition, exclusions & points to check

1995 unit shut down since August 2025, not retested since. Last maintenance stated on 25 August 2025. Analyser not included.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-042

PHILIPS CM120

PHILIPS · 1990 · Installed · shut down

Availability to be confirmed · Price on request

Source & voltageLaB6 stated; 60–120 kV, maximum 120 kV
Stated resolutionPoint resolution 0.34 nm; line resolution 0.20 nm, model data
Detection & analysisChemical analyser excluded
Stage & samplesCompuStage; model tilt up to ±70°, setup to be confirmed
Accessories & configurationSingle-tilt sample holder

Condition, exclusions & points to check

1990 unit shut down since August 2025, not retested since. Last maintenance stated on 25 August 2025. Analyser not included.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

FIB-SEM · 2Cnano reference 2CN-043

FEI Helios NanoLab 600 FIB-SEM Dual Beam Electron Microscope

FEI · Not specified · To be documented

Availability to be confirmed · Price on request

Source & voltageSchottky FE / Elstar; Sidewinder gallium ion column
Stated resolutionSEM 0.9 nm at 15 kV; at coincidence point 1 nm at 15 kV / 1.6 nm at 5 kV; other ambiguous values to be confirmed
Detection & analysisTLD SE/BSE; retractable STEM
Stage & samples5 piezo axes; XY 150 mm; Z 0–20 mm; tilt −10°/+60°
Accessories & configurationAutoProbe 200; ibss GV10x plasma

Condition, exclusions & points to check

Condition, year and voltage not provided. Some resolution conditions are incomplete: technical confirmation is essential.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-044

PHILIPS Tecnai F20 Ultra twin

PHILIPS · 2000 · Requires repair / inspection

Availability to be confirmed · Price on request

Source & voltageF20 Ultra Twin; source and voltage to be specified
Stated resolutionNot provided
Detection & analysisGatan camera reported out of service
Stage & samplesSingle- and double-tilt sample holders
Accessories & configurationIncomplete configuration

Condition, exclusions & points to check

Deinstalled and incomplete. Camera out of service; missing-item inventory and refurbishment to be specified.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

FIB-SEM · 2Cnano reference 2CN-045

FEI Strata 400 Dual Beam FIB SEM

FEI · 2005 · Installed · shut down

Availability to be confirmed · Price on request

Source & voltageSchottky Sirion; electrons 200 V–30 kV; Sidewinder Ga ions 2–30 kV
Stated resolutionSEM 1 nm at 15 kV / 2.5 nm at 1 kV; FIB 7 nm at 30 kV
Detection & analysisIn-lens SE/BSE, ETD, CDEM, IR camera
Stage & samples5 axes; XY 100 mm; Z 20 mm; tilt −10°/+60°; repeatability 0.5 µm
Accessories & configurationGIS Pt/IEE/IDep2/W; load lock; oil-free XDS10 pumping; software 3.6.3 / Windows XP

Condition, exclusions & points to check

In cold standby since early 2025. Contract until December 2024; previously reported operational. Chiller not supplied.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

FIB-SEM · 2Cnano reference 2CN-046

FEI STRATA DB235 Dual Beam FIB SEM

FEI · 2003 · Deinstalled

Availability to be confirmed · Price on request

Source & voltageDual-beam FIB-SEM; source configuration to be specified
Stated resolution<3 nm at 1 kV, WD 2 mm; 5 kV, WD 5 mm; 30 kV, WD 7 mm, beam to be confirmed
Detection & analysisSED, CDEM, TLD
Stage & samplesXY 50 mm; E-beam repeatability at 0° <1 µm; I-beam at 52° <2 µm; accuracy respectively <2 / <4 µm
Accessories & configurationXeF₂ GIS; EDX WD 5 mm

Condition, exclusions & points to check

Vacuum stated around 10⁻⁶ mbar after 24 h. Deinstalled; performance to be checked after reassembly.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-047

JEOL IT 300 LV

JEOL · Not specified · Reported operational

Availability to be confirmed · Price on request

Source & voltageConfiguration not detailed in the listing
Stated resolutionNot provided
Detection & analysisNot provided
Stage & samplesNot documented
Accessories & configurationRequest the accessory list

Condition, exclusions & points to check

JEOL IT300LV reportedly installed and operational. Year and technical documentation missing, to be confirmed before a proposal.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-048

FEI Quanta 400 FEG

FEI · Not specified · Requires repair / inspection

Availability to be confirmed · Price on request

Source & voltageFEG; 200 V–30 kV; Quanta MK1
Stated resolutionModel specifications: HV 1.2 nm at 30 kV / 3 nm at 1 kV; LV/ESEM 1.5 nm at 30 kV
Detection & analysisETD, LFD, GAD, BSE; Oxford X-MaxN 150 mm² TO BE CONFIRMED
Stage & samplesXY 100 mm; Z 60 mm; tilt −5°/+70°; 360° rotation
Accessories & configuration4pi acquisition PC; xT 2.4 software (build 2005); control PC

Condition, exclusions & points to check

Source replaced, then instrument unused; poor resolution reported. Performance to be checked during reinstallation; maintenance history unknown.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

FIB-SEM · 2Cnano reference 2CN-049

FEI STRATA DB237 Dual Beam FIB SEM

FEI · 2003 · Deinstalled

Availability to be confirmed · Price on request

Source & voltageDual-beam FIB-SEM; configuration to be specified
Stated resolution<3 nm at 1 kV, WD 2 mm; 5 kV, WD 5 mm; 30 kV, WD 7 mm, beam to be confirmed
Detection & analysisSED, CDEM, optional TLD, STEM
Stage & samplesXY 50 mm; E-beam repeatability <1 µm at 0° / I-beam <2 µm at 52°; tilting TEM grid holder
Accessories & configurationPt deposition, XeF₂, Omniprobe 100; EDX WD 5 mm

Condition, exclusions & points to check

Vacuum stated at 10⁻⁶ mbar after 24 h. Deinstalled; actual delivered configuration to be confirmed.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

FIB-SEM · 2Cnano reference 2CN-050

FEI Strata 400 Dual Beam FIB SEM

FEI · 2004 · Reported operational

Availability to be confirmed · Price on request

Source & voltageSchottky; SEM 200 V–30 kV; Ga ions 500 V–30 kV
Stated resolutionStated SEM resolution 2.5 nm at 1 kV / 1 nm at 15 kV
Detection & analysisETD, CDEM and TLD
Stage & samplesXY repeatability at 0° <0.5 µm; Ø75 mm sample compatible with load lock
Accessories & configurationGIS for etching, insulating-material and tungsten deposition; Omniprobe 200; chiller; Oneac transformer; Windows 2000 PC

Condition, exclusions & points to check

Reported operational. In-situ lift-out system and SEM/FIB/GIS software stated; exact scope to be confirmed.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

FIB-SEM · 2Cnano reference 2CN-051

FEI Versa 3D FIB SEM Dual Beam FEG

FEI · 2013 · Reported operational

Availability to be confirmed · Price on request

Source & voltageFEG SEM 200 V–30 kV, optional deceleration; Ga ions 0.5–30 kV, 1.5 pA–65 nA
Stated resolutionIon beam 7 nm at 30 kV at the coincidence point; 5 nm at optimum WD
Detection & analysisCBS-BSE, ETD-SE, STEM, ICE and IR camera
Stage & samples5-axis motorised stage
Accessories & configurationPt GIS; FEI EasyLift; chiller; plasma

Condition, exclusions & points to check

Auto Slice and View G3 functions and some equipment listed as optional. Ion resolution must not be confused with electron resolution.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-052

ZEISS Sigma 300 FEG

ZEISS · 2021 · Reported operational

Availability to be confirmed · Price on request

Source & voltageSchottky FEG; 0.02–30 kV; Gemini 1 column
Stated resolution1.2 nm at 15 kV; 2.2 nm at 1 kV
Detection & analysisIn-lens SE, ET-SE, AsB/HDAsB; EDS NOT SUPPLIED
Stage & samples5 eucentric axes; XY 125 mm; Z 50 mm; tilt −10°/+90°; continuous rotation
Accessories & configurationDAEIL DVIA-M active vibration isolation

Condition, exclusions & points to check

2021 unit reportedly functional with no known fault. Maintenance history not specified.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-053

TFS Phenom ProX Desktop SEM

TFS · 2016 · Reported operational

Availability to be confirmed · Price on request

Source & voltageThermionic CeB6; 5/10/15 kV presets and one user setting
Stated resolution14 nm stated
Detection & analysis4-segment silicon BSE; colour navigation; LN₂-free SDD EDS 25 mm², 140 eV at Mn Kα
Stage & samplesMotorised XY 18 mm; standard sample Ø25 × 30 mm
Accessories & configurationPro Suite, EDS mapping and line profiles, diaphragm pump, PC, screen, sample holder and charge reduction

Condition, exclusions & points to check

Reported operational. Inclusion of the 3D roughness reconstruction module to be confirmed.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-054

PHILIPS TECNAI T12 G2 spirit twin

PHILIPS · 2014 · Packed / crated

Availability to be confirmed · Price on request

Source & voltageSource and voltage not detailed in the listing
Stated resolutionNot provided
Detection & analysisGatan Orius SC200D; AMETEK-SAMx EDS 10 mm²
Stage & samplesConfiguration to be specified
Accessories & configurationOther accessories not documented

Condition, exclusions & points to check

2014 unit packed / crated; separate from the other two 2014 Spirit Twin units.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-055

PHILIPS TECNAI T12 G2 spirit twin

PHILIPS · 2014 · Installed · shut down

Availability to be confirmed · Price on request

Source & voltageSource and voltage not detailed in the listing
Stated resolutionNot provided
Detection & analysisGatan Orius SC200D; SGX Sensortech EDX
Stage & samplesConfiguration to be specified
Accessories & configurationOther accessories not documented

Condition, exclusions & points to check

2014 unit installed and shut down; power-up reportedly possible.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-056

PHILIPS TECNAI T12 G2 spirit twin

PHILIPS · 2014 · Installed · shut down

Availability to be confirmed · Price on request

Source & voltageSource and voltage not detailed in the listing
Stated resolutionNot provided
Detection & analysisGatan Orius SC200D; SGX Sensortech EDX
Stage & samplesConfiguration to be specified
Accessories & configurationOther accessories not documented

Condition, exclusions & points to check

2014 unit installed and shut down; return to operation must be checked.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-057

PHILIPS EM420

PHILIPS · 1985 · Requires repair / inspection

Availability to be confirmed · Price on request

Source & voltageThermionic LaB6 or tungsten depending on configuration; 40–120 kV
Stated resolutionPoint resolution 0.34 nm; line resolution 0.20 nm
Detection & analysisBottom-mounted AMT CCD 4 Mpix
Stage & samples±45° tilt; two Gatan double-tilt and one single-tilt sample holders
Accessories & configurationHaskris chiller and spare pump, six Wehnelt cylinders and spare parts

Condition, exclusions & points to check

Initially offered for parts or as non-functional. Full testing required despite the stated packed condition.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

SEM · 2Cnano reference 2CN-058

ZEISS Sigma 500 FEG

ZEISS · 2017 · Reported operational

Availability to be confirmed · Price on request

Source & voltageSchottky FEG; 20 V–30 kV; Gemini 1
Stated resolution0.8 nm at 15 kV; STEM 0.8 nm at 30 kV; 1.3 nm at 1 kV
Detection & analysisInlens SE, ETSE and BSE; EDS NOT SUPPLIED
Stage & samples5-axis motorised eucentric stage; travel to be confirmed
Accessories & configurationibss plasma, multi-screen PC and laptop

Condition, exclusions & points to check

2017 unit reportedly functional with no known fault. Service history not specified.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-059

FEI Tecnai T12 G2 Spirit LaB6 TEM

FEI · 2008 · Requires repair / inspection

Availability to be confirmed · Price on request

Source & voltageThermionic LaB6; stated nominal range 20–120 kV
Stated resolutionPoint resolution 0.344 nm; line resolution 0.204 nm, stated specifications
Detection & analysisEagle CCD 4K, the only listed detector
Stage & samplesCompuStage; XY 1 mm; α ±70°
Accessories & configurationThermoFlex 2500, PVP/ODP/IGP pumps, PC and two screens, two consoles

Condition, exclusions & points to check

Faulty high-voltage ceramics: reportedly unable to exceed 60 kV in its current condition. Replacement required; manufacturer contract reported.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.

TEM · 2Cnano reference 2CN-060

FEI Tecnai G2 Spirit BioTWIN LaB6 TEM

FEI · 2008 · Reported operational

Availability to be confirmed · Price on request

Source & voltageLaB6; BioTWIN; continuous 20–120 kV, stated minimum step 10 V
Stated resolutionStated line resolution 0.34 nm; point resolution not provided
Detection & analysisSide-mounted EMSIS Veleta CCD and PC; bottom plate camera
Stage & samplesXY 2 / 2 mm; Z 0.75 mm; tilt ±80° depending on sample holder
Accessories & configurationCompressor, pumps, single grid holder; film consumables not supplied

Condition, exclusions & points to check

No chiller: connected to a central system. Regular operation reported; preventive maintenance in late September 2026 and Thermo Fisher contract until deinstallation.

Information recorded on 31 October 2026. Stated values do not replace an acceptance test; condition, accessories and services will be specified in the 2Cnano quotation.